logo
Shanghai Tankii Alloy Material Co.,Ltd
Shanghai Tankii Alloy Material Co.,Ltd
producten
Thuis /

producten

Draagbaar PVC geïsoleerd met metalen omhulsel Pt100 & RTD sensor voor temperatuurmeting in de voedings- en drankenindustrie

Productdetails

Place of Origin: China

Merknaam: Tankii

Certificering: ISO9001

Model Number: RTD /pt100 cable

Betaling & het Verschepen Termijnen

Min. bestelaantal: 200 tot 1000 m

Prijs: USD0.2~2.5/m

Verpakking Details: In rollen, in kartonnen doos/houtdoos

Delivery Time: 5~20 days as orders

Payment Terms: L/C, T/T

Levering vermogen: 10000m per maand

Krijg Beste Prijs
Contact opnemen
Specificaties
Markeren:

Voedsel- en drankenindustrie Pt100 sensor

,

Draagbare PVC geïsoleerde Pt100 sensor

,

Metalen schede Pt100 sensor

Item:
Portable PVC Insulated With Metal Sheath Pt100 & RTD Sensor Used For Food And Beverage Industry Temperature Measurement
Application:
Food and Beverage Industry
Cable Jacket:
Fiberglass, PVC, FEP, stainless steel sheath
Isolatie soorten:
PVC, FEP, kapton, PFA/glasvezel
Temperatuurbereik van isolatie:
tot en met 450
Cable Length:
100m, 200m, 300m as per your request
MOQ:
500M or 1000M as per size
Cable section area:
0.2mm2,0.5mm2 1.0mm2,1.5mm2,
Item:
Portable PVC Insulated With Metal Sheath Pt100 & RTD Sensor Used For Food And Beverage Industry Temperature Measurement
Application:
Food and Beverage Industry
Cable Jacket:
Fiberglass, PVC, FEP, stainless steel sheath
Isolatie soorten:
PVC, FEP, kapton, PFA/glasvezel
Temperatuurbereik van isolatie:
tot en met 450
Cable Length:
100m, 200m, 300m as per your request
MOQ:
500M or 1000M as per size
Cable section area:
0.2mm2,0.5mm2 1.0mm2,1.5mm2,
Beschrijving
Draagbaar PVC geïsoleerd met metalen omhulsel Pt100 & RTD sensor voor temperatuurmeting in de voedings- en drankenindustrie

Portable PVC Insulated With Metal Sheath Pt100 & RTD Sensor Used For Food And Beverage Industry Temperature Measurement

A PT100 cable measures temperature based on the principle of the positive temperature coefficient of platinum resistance. Here's a detailed explanation:
 

Measurement Process: An electrical current is passed through the platinum resistance element in the PT100 cable. As the temperature changes, the resistance of the platinum element also changes accordingly. By measuring the change in resistance, the corresponding temperature can be determined. Usually, a Wheatstone bridge circuit or other measurement circuits are used to accurately measure the resistance value of the PT100. The measurement circuit converts the resistance change into a voltage or current signal, which can be read and processed by a temperature - measuring instrument or a data acquisition system. After calibration, the instrument can directly display the measured temperature value.

To install a PT100 cable for accurate temperature measurement, the following steps and considerations are important:
 
  1. Select the appropriate cable: Choose a PT100 cable with the right specifications for your application, considering factors such as the temperature range, environmental conditions, and required accuracy. For example, in high - temperature environments, cables with high - temperature - resistant insulation should be selected.
  2. Prepare the installation site: The installation location should be free from mechanical vibrations, strong electromagnetic fields, and direct sunlight. Ensure that the surface where the sensor is to be installed is clean, flat, and free from dirt, oil, and other contaminants. If measuring the temperature of a liquid, make sure the sensor is installed in a location where it can be fully immersed in the liquid and is not affected by flow disturbances.
  3. Proper sensor placement: For measuring the temperature of solids, the PT100 sensor should be in good thermal contact with the object. This can be achieved by using thermal paste or adhesive to attach the sensor firmly to the surface. If possible, insert the sensor into a drilled hole in the object to ensure better heat transfer. When measuring air temperature, the sensor should be placed in a well - ventilated area to ensure accurate measurement of the ambient air temperature.
  4. Cable routing: Route the cable away from sources of interference, such as power cables and electrical equipment that may generate electromagnetic fields. Use cable trays, conduits, or armored cables to protect the PT100 cable from physical damage. Avoid sharp bends and twists in the cable, as these can affect the accuracy of the measurement by changing the resistance of the cable.
  5. Connection and termination: Make sure the connections at both ends of the PT100 cable are secure and free from corrosion. Use appropriate terminal blocks or connectors to connect the cable to the measuring instrument. Follow the manufacturer's instructions for proper termination to ensure accurate measurement. In some cases, a three - wire or four - wire connection method may be used to compensate for the resistance of the cable itself and improve measurement accuracy.
  6. Calibration: Before installation and periodically after installation, calibrate the PT100 cable and sensor system to ensure accurate temperature measurement. Calibration can be performed using a calibrated temperature source and a precision measuring instrument. Compare the measured values with the known reference temperatures and adjust the system if necessary.
  7. Sealing and protection: If the installation environment is humid or dusty, use appropriate sealing materials to protect the PT100 sensor and cable connections from moisture and dust ingress. This helps to prevent corrosion and ensure the long - term stability and accuracy of the measurement.

 

 

More pictures of our cables:

Draagbaar PVC geïsoleerd met metalen omhulsel Pt100 & RTD sensor voor temperatuurmeting in de voedings- en drankenindustrie 0

Draagbaar PVC geïsoleerd met metalen omhulsel Pt100 & RTD sensor voor temperatuurmeting in de voedings- en drankenindustrie 1

Draagbaar PVC geïsoleerd met metalen omhulsel Pt100 & RTD sensor voor temperatuurmeting in de voedings- en drankenindustrie 2

FAQ:

Q: What is the brand name of this Thermocouple Cable?

A: The brand name of this Thermocouple Cable is Tankii.

Q: What are the different model numbers available for this Thermocouple Cable?

A: The different model numbers available for this Thermocouple Cable are KX/KC, JX, EX, TX, NX, SC, RTD .

Q: Where is this Thermocouple Cable manufactured?

A: This Thermocouple Cable is manufactured in China.

Q: What are the temperature ranges supported by this Thermocouple Cable?

A: The temperature ranges supported by this Thermocouple Cable vary depending on the model number. Please refer to the product specifications for more information.

Q: Is this Thermocouple Cable suitable for use in harsh industrial environments?

A: Yes, this Thermocouple Cable is designed to be durable and reliable in harsh industrial environments.

 

Our factory:

Draagbaar PVC geïsoleerd met metalen omhulsel Pt100 & RTD sensor voor temperatuurmeting in de voedings- en drankenindustrie 3

Gelijkaardige Producten
Verzend uw onderzoek
Gelieve te verzenden ons uw verzoek en wij zullen zo spoedig mogelijk antwoorden op u.
Verzend